Specifications
Section 4. Sensor Installation 
FIGURE 4.12-5. SR50A - Mounted using Nurail and C2151 Mounting 
Stem 
SR50A with 6-plate gill radiation shield – the picture below shows the 
SR50A stem attachment 
4.13 CS616 Water Content Reflectometer 
Probe rods can be inserted vertically or horizontally into the soil surface, as 
shown in Figure 4.13-1, or buried at any orientation to the surface. A probe 
inserted vertically into a soil surface will give an indication of the water 
content in the upper 30 cm of soil. Horizontal installation will detect the 
passing of wetting fronts. Insertion at a 30 degree angle with the surface will 
measure water content in the upper 15 cm of soil. 
Probes must be inserted such that no air voids are created around the rods, and 
that the rods remain as parallel as possible. Use the 14383 probe insertion 
guide to minimize errors due to improper insertion. 
The standard calibration for the CS616 probe, as programmed in Short Cut, is 
valid for loamy soils with low organic content. In other types of soils, 
4-14 