Specifications
Section 4. Sensor Installation 
4.9 CS100 or CS106 Barometric Pressure Sensor 
Mount the CS100 or CS106 to the enclosure backplate. 
1.  Mount the barometer to the mounting plate using the two screws and 
grommets provided. 
4.10 Texas Electronics Tipping Bucket Rain Gages 
(TE525, TE525WS, TE525MM) 
1.  Mount the rain gage to a CM300-series pole or a user-supplied pole as 
shown in Figure 4.10-1. Mounting the gage directly to the tripod or tower 
is not recommended. 
2.  Dig a 6" diameter hole 24" deep. 
3.  Center a 1 1/4" to 2" IPS pipe in the hole and fill the hole with concrete. 
Use a level to plumb the pipe as the hole is filled. 
4.  After the concrete has cured, attach the rain gage to the top of the pipe 
with the hose clamps provided. Route the sensor lead to the tripod in 
plastic or metal conduit. 
TE525
Hose Clamp
(2) Places 
FIGURE 4.10-1. TE525 Texas Electronics Rain Gage 
4-9 