Section 4. Sensor Installation 
4.4 Licor Silicon Radiation Sensors (LI200X, LI200S, 
LI190SB) 
Mount the Radiation Sensor to the LI2003S Base and Leveling Fixture as 
shown in Figure 4.4-1. 
1.  Position the base of the sensor in the mounting flange on the LI2003S, and 
tighten the set screw with the allen wrench provided. Adjust the three 
leveling screws flush with the bottom of the LI2003S. 
2.  Mount the LI2003S to the CM225 (Section 2.2) using the three mounting 
screws provided. Do not tighten the screws at this time. 
3.  Level the LI2003S using the bubble level and leveling screws and tighten 
the mounting screws. Remove the red protective cap prior to use. 
Bullseye 
level 
CM225
(3) Leveling 
Screws 
(3) Mounting 
Screws 
Senso
r
FIGURE 4.4-1. LI200X/LI200S/LI190SB and LI2003S Leveling Fixture 
4.5 107/108 Temperature Probe 
Mount the 107 temperature probe inside the 41303-5A 6-plate radiation shield 
as shown in Figure 4.5-1. 
1.  Loosen the two mounting clamp screws on the base of the radiation shield. 
Insert the 107 probe through the mounting clamp until the white heat 
shrink is even with the bottom of the clamp. 
2.  Tighten the two screws evenly until the clamp is snug against the sensor 
lead. 
4-4 