Specifications
Section 4. Sensor Installation 
4.3 03002 RM Young Wind Sentry Wind Set 
The 03002 can be mounted directly to the mast, or to the CM202, CM204, or 
CM206 Crossarm. 
4.3.1 03002 Mounted to the Mast 
1.  Slide the crossarm mounting bracket onto the mast. Orient the crossarm 
so the vane end points north, and tighten the band clamp (see Section 4.19 
for final calibration). 
2.  Attach the cup assembly to the anemometer shaft using the allen wrench 
provided. 
4.3.2 03002 Mounted to CM202, CM204, or CM206 Crossarm 
Mount the 03002 to the crossarm as shown in Figure 4.3-1. 
1.  Attach the CM220 bracket on the crossarm via the U-bolt and nuts. 
2.  Position the top of the mounting post 5" above the CM220 bracket and 
tighten the set screws. 
3.  Slide the crossarm mounting bracket onto the mounting post. Orient the 
crossarm so the vane end points north, and tighten the band clamp (see 
Section 4.19 for final calibration). 
4.  Attach the cup assembly to the anemometer shaft using the allen wrench 
provided. 
FIGURE 4.3-1. 03002 Mounted to a CM200-series Crossarm 
4-3 