Specifications
Section 2. UT10 Tower Installation 
4 AWG Wire 
Ground Rod 
12 AWG Wire 
FIGURE 2.1-5. Tower Grounding 
2.2 Sensor Mounting Brackets 
Sensor mounting brackets provide a means of mounting the sensors to the 
tower. General orientation of the mounting brackets is shown in Figure 2.2-1. 
2.2.1 Crossarm Mounting 
2.2.1.1 CM202, CM204, CM206 Crossarms 
1.  Attach the crossarm at the desired height via the provided u-bolts and nuts 
(Figure 2.2-2). 
2.2.1.1 019ALU Crossarm 
Attach the 019ALU crossarm to the mast as shown in Figure 2.2-3. 
2.  Position the middle NU-RAIL so that it rests on top of the bell reducer. 
Orient the 019ALU in a East/West direction, with the 3/4” NU-RAIL 
facing East and tighten the set screws. If the 019ALU is used with the 025 
Crossarm Stand (Section 2.2.4), orient the 019ALU North/South, with the 
3/4” NU-RAIL facing South. 
3.  Install the lightning rod to the mast as shown in Figure 2.2-3. Loosen the 
two screws on the lightning rod mounting bracket. Position the mounting 
bracket 2" down from the top of the mast and tighten both screws evenly. 
Make sure the lightning rod set screw is tight. 
2-5 