Specifications

TEAM Climate Monitoring Protocol 3.1
55
2. R
R
e
e
m
m
o
o
v
v
e
e
t
t
h
h
e
e
s
s
e
e
n
n
s
s
o
o
r
r
h
h
e
e
a
a
d
d
.
.
Unhook one of the temperature sensors and pull it out of the
housing without disconnecting the cables from the sensor to the cabling box. Once the sensor
is out, pull out the sensor head at the end.
3. R
R
e
e
p
p
l
l
a
a
c
c
e
e
t
t
h
h
e
e
s
s
e
e
n
n
s
s
o
o
r
r
h
h
e
e
a
a
d
d
.
.
Write down the serial number of the replacement sensor head
in the
Sensor Installation/Calibration Form
(Appendix A.4). Insert the replacement head into
the probe (there is only one way to do it).
4. P
P
u
u
t
t
b
b
a
a
c
c
k
k
e
e
v
v
e
e
r
r
y
y
t
t
h
h
i
i
n
n
g
g
i
i
n
n
p
p
l
l
a
a
c
c
e
e
.
.
Put the probe back in the radiation shield housing making
sure that the two sensor heads are not touching each other or the walls. Clamp back the
sensor housing tube into the fan housing section of the shield.
5. S
S
e
e
n
n
d
d
t
t
h
h
e
e
s
s
e
e
n
n
s
s
o
o
r
r
h
h
e
e
a
a
d
d
o
o
u
u
t
t
f
f
o
o
r
r
c
c
a
a
l
l
i
i
b
b
r
r
a
a
t
t
i
i
o
o
n
n
.
.
Complete a
Sensor Calibration Metadata
Form
(Appendix A.5) for each sensor that is sent out for calibration. Obtain an RMA number
from the closest regional Campbell Scientific office and mail the sensor head out. When the
sensor comes back, fill in the rest of the
Sensor Calibration Metadata Form
and keep the
sensor as a duplicate. Repeat the process above a year later when the other sensor in the pair
will need to be recalibrated.
6. S
S
u
u
b
b
m
m
i
i
t
t
t
t
h
h
e
e
i
i
n
n
f
f
o
o
r
r
m
m
a
a
t
t
i
i
o
o
n
n
t
t
o
o
t
t
h
h
e
e
T
T
E
E
A
A
M
M
p
p
o
o
r
r
t
t
a
a
l
l
.
.
The information on the
Sensor
Installation/Calibration Form
should be always be submitted to the TEAM portal (see Section
6.5.4). When a sensor is sent out for calibration, also submit the information from the
Sensor
Calibration Metadata Form
to the TEAM portal (Section 6.5.4 as well).
F
F
i
i
g
g
u
u
r
r
e
e
2
2
4
4
.
.
D
D
i
i
a
a
g
g
r
r
a
a
m
m
i
i
l
l
l
l
u
u
s
s
t
t
r
r
a
a
t
t
i
i
n
n
g
g
o
o
p
p
e
e
r
r
a
a
t
t
i
i
o
o
n
n
a
a
n
n
d
d
c
c
a
a
l
l
i
i
b
b
r
r
a
a
t
t
i
i
o
o
n
n
s
s
c
c
h
h
e
e
d
d
u
u
l
l
e
e
s
s
f
f
o
o
r
r
T
T
e
e
m
m
p
p
e
e
r
r
a
a
t
t
u
u
r
r
e
e
/
/
R
R
H
H
s
s
e
e
n
n
s
s
o
o
r
r
s
s
(
(
a
a
l
l
s
s
o
o
a
a
p
p
p
p
l
l
i
i
e
e
s
s
t
t
o
o
t
t
h
h
e
e
r
r
a
a
d
d
i
i
a
a
t
t
i
i
o
o
n
n
s
s
e
e
n
n
s
s
o
o
r
r
s
s
)
)
.
.
S
S
e
e
n
n
s
s
o
o
r
r
s
s
a
a
r
r
e
e
s
s
e
e
n
n
t
t
o
o
u
u
t
t
f
f
o
o
r
r
c
c
a
a
l
l
i
i
b
b
r
r
a
a
t
t
i
i
o
o
n
n
a
a
t
t
t
t
h
h
e
e
e
e
n
n
d
d
o
o
f
f
t
t
h
h
e
e
i
i
r
r
s
s
e
e
c
c
o
o
n
n
d
d
y
y
e
e
a
a
r
r
o
o
f
f
o
o
p
p
e
e
r
r
a
a
t
t
i
i
o
o
n
n
e
e
x
x
c
c
e
e
p
p
t
t
f
f
o
o
r
r
t
t
h
h
e
e
f
f
i
i
r
r
s
s
t
t
y
y
e
e
a
a
r
r
,
,
w
w
h
h
e
e
n
n
s
s
e
e
n
n
s
s
o
o
r
r
2
2
i
i
s
s
s
s
e
e
n
n
t
t
o
o
u
u
t
t
(
(
t
t
o
o
g
g
e
e
t
t
s
s
e
e
n
n
s
s
o
o
r
r
s
s
o
o
u
u
t
t
o
o
f
f
s
s
y
y
n
n
c
c
a
a
n
n
d
d
a
a
l
l
l
l
o
o
w
w
a
a
l
l
t
t
e
e
r
r
n
n
a
a
t
t
i
i
o
o
n
n
)
)
.
.
D
D
u
u
r
r
i
i
n
n
g
g
y
y
e
e
a
a
r
r
2
2
a
a
n
n
d
d
a
a
f
f
t
t
e
e
r
r
w
w
a
a
r
r
d
d
s
s
t
t
h
h
e
e
r
r
e
e
a
a
r
r
e
e
a
a
l
l
w
w
a
a
y
y
s
s
2
2
s
s
e
e
n
n
s
s
o
o
r
r
s
s
o
o
p
p
e
e
r
r
a
a
t
t
i
i
o
o
n
n
a
a
l
l
a
a
n
n
d
d
o
o
n
n
e
e
i
i
s
s
o
o
u
u
t
t
f
f
o
o
r
r
c
c
a
a
l
l
i
i
b
b
r
r
a
a
t
t
i
i
o
o
n
n
(
(
a
a
n
n
d
d
c
c
a
a
n
n
b
b
e
e
u
u
s
s
e
e
d
d
a
a
s
s
a
a
s
s
p
p
a
a
r
r
e
e
w
w
h
h
e
e
n
n
i
i
t
t
r
r
e
e
t
t
u
u
r
r
n
n
s
s
)
)
.
.
6.5.2
Precipitation gauge (TB4)
E
E
q
q
u
u
i
i
p
p
m
m
e
e
n
n
t
t
/
/
s
s
u
u
p
p
p
p
l
l
i
i
e
e
s
s
n
n
e
e
e
e
d
d
e
e
d
d
:
:
Pen/Pencil
Allen wrench
Blank
Sensor Installation/Calibration Form
Blank
Sensor Calibration Metadata Form