Instruction manual

Section 5. Programming the Datalogger
5-19
*Table 1 Program
01: 2 Execution Interval (seconds)
;set up the filter and then send string 101.
1: SDM-SIO4 (P113)
1: 1 Reps
2: 0 Address
3: 1 Send/Receive Port 1
4: 2304 Command
5: 8101 1st Parameters
6: 1999 2nd Parameters
7: 0 Values per Rep
8: 0 Loc [ ]
9: 1.0 Mult
10: 0.0 Offset
;wait long enough for sensor to send data.
2: Excitation with Delay (P22)
1: 1 Ex Channel
2: 0 Delay W/Ex (units = 0.01 sec)
3: 4 Delay After Ex (units = 0.01 sec)
4: 0 mV Excitation
;get data from SDM-SIO4 and put into locations 1 and 2.
3: SDM-SIO4 (P113)
1: 1 Reps
2: 0 Address
3: 1 Send/Receive Port 1
4: 4 Command
5: 0 1st Parameters
6: 0 2nd Parameters
7: 2 Values per Rep
8: 1 Loc [ number ]
9: 1.0 Mult
10: 0.0 Offset
;At zero minutes into a 10 minute interval set the output
;so that the data from the sensor will be stored into
;final storage.
4: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 10 Interval (same units as above)
3: 10 Set Output Flag High (Flag 0)
;Time stamp.
5: Real Time (P77)
1: 1110 Year,Day,Hour/Minute