Instruction manual

Section 4. Programming the SDM-SIO4
4-2
The hex. number must always be two ASCII characters.
Control characters can be entered for all commands in a similar way:
^M is carriage return, ^J line feed etc.
^^ means ^
"" means "
]] means ]
&& means &
&0d means line feed
&hex,hex used to enter 2-character hex. codes (0-9, A-F)
4.3 Basic Commands
fltst [string number] ["filter definition"]
This command stores a filter definition to a string number 0..255.
Example: fltst 22 "ccci[x]Fs"
The above example stores the filter definition in filter string 22.
See Section 3 for filter types.
strst [string number] ["string definition"]
This command stores a user text string definition to a string number 0..255.
Example: strst 22 """This is a string""^M^J"
The above example stores the string definition "This is a string"
crlf in string 22.
This string will include the two quotation marks, as shown.
fmtst [string number] ["format definition"]
This command will store a formatter definition to a string number 0..255.
Example: fmtst 22 "i[volts=]f4:2" (result would be, for example,
volts=12.7)
The above example stores the formatter definition in string 22.
See Section 3 for formatter types.
strdelete [string number]
This command deletes a stored filter, formatter or text string 0..255 from
memory.
NOTE