2.3 Temperature and Humidity Ranges
Temperature
Range
Minimum
Maximum
Notes
Standard range -20ºC +50ºC
Extended range
(optional)
-40ºC +80ºC (Contact Campbell Scientific
for further extended
temperature requirements)
Humidity Minimum Maximum Notes
Standard range 0% 95% (non-condensing)
2.4 Physical Parameters
Main body
Height: 2.2” H (5.4 H cm)
Width: 3.1” W (8.0 W cm)
Depth: 1.0” D (2.5 D cm)
Main body including base mounting flange
Height: 2.2” H (5.4 H cm)
Width: 4.5” W (11.2 W cm)
Depth: 1.0” D (2.5 D cm)
Weight: 2.8 oz. (80 g) (approximately)
Mounting centers are 10.2 cm (4”)
2.5 Datalogger Compatibility
The SDM-SIO1 is currently supported in operating systems of the CR800/850,
CR1000 and CR3000 dataloggers. Please contact Campbell Scientific for
details of support in the CR5000 and CR9000X, which may be made available
at a later date.
3. Installation
The SDM-SIO1 is normally mounted on the backplane of a Campbell
Scientific enclosure using the screws and plastic inserts provided. The SDM-
SIO1 is designed to be installed in a dry, non-condensing environment. Before
fixing it, select and set the SDM address as this requires access to the side of
the case. The SDM address is set with a screw driver. Below is a list of the
possible SDM addresses and their relationships to the COM port number in the
SerialOpen command.
5