Specifications
Section 2. Hardware Installation
NOTE
The splice and wire nut must be completely immersed into the
silicon gel inside the splice tube to be waterproof.
2) Mount the surge protector box to a flat surface within 5 feet of the PC's
serial port. Ground the center terminal to an earth (or building) ground
using the 14 AWG wire.
3) Connect the 5-foot patch cable from the surge box to the Rad Modem.
Fasten the cable to the strain relief tab with a cable tie. Connect the Rad to
the PC's serial port with the 9-to-25 pin serial cable.
4) Route the user-supplied cable from the remote splice to the surge
protector. Connect it and the 5-foot patch cable to the surge protector.
SW-12V 12V 5V 6H 6L - + - +
XMT RCV
See Figure 2.5-1 for close-up
FIGURE 2.5-4. Short-Haul Modem Wiring Diagram
2.5.4 RF450 900 MHz, 1 Watt Spread Spectrum Radio
The RF450 is a license free 1 watt spread spectrum radio. Communication is
strictly line-of-sight. Communication distance is dependant on antennas,
cabling, and terrain (please note that line-of-sight obstructions and RF
interference will affect transmission distance).
2-30