Product manual
RAWS-H Remote Automated Weather Station 
4.6 Barometric Pressure 
The barometric pressure sensor (part #CS100-QD) is mounted inside the 
RAWS environmental enclosure and the sensor wires are attached to the 
CR1000 printed circuit board wiring panel. 
CS100 Barometric Pressure Sensor wires attached to CR1000 Wiring 
Panel 
CS100 Blue wire  to CR1000 wiring panel  5H 
CS100 Yellow wire  to CR1000 wiring panel  AG 
CS100 Red wire  to CR1000 wiring panel  12V 
CS100 Clear wire  to CR1000 wiring panel  Ground 
CS100 Black wire  to CR1000 wiring panel  Ground 
CS100 Green wire  to CR1000 wiring panel  C4 
The CS100 is sensitive to static when the back plate is 
removed. To avoid damage, take adequate anti-static 
measures when handling this sensor. 
CAUTION 
5. Equipment Wiring and Troubleshooting 
5.1 Solar Panels 
5.1.1 General Description, Solar Panel 
The RAWS Solar Panel is a photovoltaic power source used for charging lead 
acid batteries. The SP20-Handar 20 watt solar panel is used for system 
configurations that have higher-than-average power requirements. It is also 
recommended for use at higher elevations and latitudes. The solar panel 
should be mounted facing south if located in the northern hemisphere, or facing 
north in the southern hemisphere. 
The SP10-Handar 10 watt solar panel is recommended for a RAWS where NO 
communication equipment is used. The SP20-Handar 20 watt solar panel is 
recommended for a RAWS where communication equipment is used (i.e., 
GOES, voice, cell phone, or radio). 
If the user supplies a solar panel for the RAWS, use an 
unregulated solar panel. The solar panel size depends on the 
station power requirements, specifically the communication 
equipment selected for the station. 
NOTE 
The SP10-Handar solar panel outputs 0.59 Amps, 8.9 Watts typical peak 
power. 
The SP20-Handar solar panel outputs 1.17 Amps, 18 Watts typical peak power. 
5.1.2 Wiring, Solar Panel 
The RAWS-Solar Panel attaches to the connector panel labeled “BATT 
CHARGER/SOLAR PANEL”. Inside the RAWS environmental enclosure the 
“BATT CHARGER/SOLAR PANEL” connector pin A and pin B are wired to 
the CH100 charger/regulator “CHG” and “CHG” ports. Polarity does not 
6 