7 Connections to the Datalogger
1. If connecting to a CR1000, CR800 or CR23X and you would like to connect to
the RS232 port you will require a null modem cable, Campbell Scientific part
number L18663.
2. Connect one end of the Null Modem Cable to the Raven X modem and the
other to the datalogger’s RS232 port.
3. If connecting to any datalogger’s CS I/O port you will require an SC932A
interface from Campbell Scientific. Connect the supplied black SC12 cable to
the datalogger side of the SC932A interface and then to the CS I/O port of the
datalogger.
Connect the DCE Device side of the SC932A interface to the Raven X
modems RS232 port using the supplied straight through serial cable L10873.
4. In some cases it may be desirable to connect using the Ethernet interface
available on the Raven X. To do this you will require a CR1000 or CR3000