Instruction manual
Raven X-HSPA Sierra Wireless Cellular Modem
19
sure that the Network and Service light is solid. If the Network light is flashing the
modem has not registered. If the Service light is not lit but the Network light is, the
modem has registered on the network, however, there is no HSUPA/HSDPA or UMTS
coverage and the modem has registered on the EDGE or GPRS network. If the Modem’s
Network light is not solid after this time contact Campbell Scientific Canada at 780-454-
2505 for support.
6 Setup LoggerNet
1. Select Add Root | IP Port
2. Add a Datalogger to the IP Port
3. On the IP Port page:
a. Select Communications Enabled.
b. In the Internet IP Address field, enter the IP address of the modem
followed by .eairlink.com and the Device port ID. This number is :6785
and is found in the “Common” tab settings of the Raven modem (see
below).
c. Extra response time should be 10 - 12 seconds.
d. Click “Apply”.
4. Click on the CR1000 and change the Maximum Packet size from the default
1000 to 400 bytes. Please also make sure that the proper Pakbus address is
in the Pakbus address field.
5. Click “Apply”.