Specifications
RavenXTG Sierra Wireless Cellular Modem
4. Configuration
4.1 Base Station Requirements for RavenXTG
PC running Campbell Scientifics’ LoggerNet or PC400 software, with access
to the internet.
4.2 Datalogger Site Equipment
• Raven modem with power cable (included with modem).
• Datalogger—21X, CR510, CR10(X), CR23X, CR7, CR1000, CR5000,
CR3000, CR800.
• SC105 or SC932A Interface—connects the modem to the 21X, CR510,
CR10(X), CR7, or other dataloggers’ CS I/O port.
The SC105 must be configured for use with the modem using the Device
Configuration Utility. Settings should be:
CS I/O Mode: SDC Address 7
RS-232 Mode: Modem
Baud Rate: 115.2K or 9600 baud depending on datalogger model
8 data bits, 1 stop bit, no parity
• PN 18663 Null Modem Cable—connects the modem to the CR23X,
CR3000, CR800, CR2XX, CR1000 or CR5000 RS-232 port.
If you have a black SC12 cable that is not Rev 1 or newer (as
indicated on cable), it is a CS I/O cable only and will not work
for RS-232. Connect the black SC12 cable between the
datalogger and the SC932A. Use a 9-pin serial cable or a blue
ribbon cable between the phone and the SC932A.
NOTE
3