Specifications

RavenXTG Sierra Wireless Cellular Modem
Baud rate changes require the modem to be reset before the
change takes affect. Click the Reset icon in AceManager to the
reset the modem and implement the change.
NOTE
Verify the APN has been entered in the NETAPN and +CGDCONT fields as
shown above (where I2GOLD is the APN).
e. If an SC105 interface is used, its default baud rate of 9600 will have to be
changed to match the baud rate of the modem (using CSI’s DevConfig
utility).
f. Check the Network light. Network – indicates a successful connection to
the cellular network with an IP Address given and a channel acquired.
g. Make sure the modem has sufficient power.
h. Check the signal strength (make sure your antenna is properly connected
and oriented). Signal strength should be in the -51 to -90 range (-51 is a
strong signal, -90 is a weak signal).
i. If you have a Static IP account, verify the Static IP Address. Preceding
zeros in the IP address are not entered in LoggerNet/PC400.
j. If you have a Dynamic IP account, you will need to have a DDNS
(dynamic domain name server) name that LoggerNet can reference to
make the connection (Section 5).
k. Connect with the modem through the serial port using AceManager. If the
modem has been configured for “PPP” (see appendix B), then you may
have to check the “Use SOS Mode” box.
From the “Status” group, make sure the “Network State” is “Network
Ready”, and note the “Network IP” address. This is the current IP address
for the modem (a dynamic IP address may change when the modem is
reset). Try connecting to this IP address using LoggerNet. If LoggerNet
20