User guide
SAA CR Logger Integration Guide
May 2012 11
Figure 7.1 Selecting File Control in the LoggerNet Connect utility.
Once the File Control window opens, the ‘Send’ option is used to place the SAA_Include file on the
CR1000, as illustrated in Figure 7.2. The ‘Run Now’ and ‘Run On Power-up’ options should be deselected
when prompted (Figure 7.3) (since the SAA_Include file will not run as a standalone application).
Note: The SAA_Include file must be placed on the CR1000 before the main program will run. This
is accomplished using ‘File Control’ from the Connect utility.
The main program file can be placed in the same way by using the ‘File Control’ and ‘Send’ options.
When uploading the main program file, the ‘Run Now’ and ‘Run On Power-up’ options should be
selected. Note since the run program options are selected, the main program will compile at this point
(Figure 7.4). Alternatively the ‘Save, Compile and Send’ option in the CRBasic Editor can be used. When
prompted for Run Options, ‘Run Now’ and ‘Run On Power-up’ should be selected.
Note: If you run the program to test the logger set-up, make sure to remove garbage data from
the logger by clicking the ‘Stop Program’ button. When prompted, choose the ‘Clear the
Program’ option. When finished setting up the site, click ‘Run Options’ and select ‘Run Now’ and
‘Run on Power-up’ to start collecting data. To make sure no garbage data is left behind, when
prompted select ‘Delete associated data tables created by’.