Product manual

RavenXTG GPRS/EDGE Sierra Wireless Cellular Modem
Typical Current Drain (at 12 Vdc): 50 mA dormant (idle for 10 to 20 seconds),
120 mA transmit/receive
Input Voltage Range: 6 to 28 Vdc
Operating Temperature Range: –30° to +65°C
Operating Humidity Range: 5% to 95% RH non-condensing
Status LEDs: Power, Network, Signal, Activity
Dimensions
Width: 7.6 cm (3 in)
Depth: 2.5 cm (1 in)
Length: 10 cm (4 in)
Weight: <0.5 kg (<1 lb)
4. Configuration
4.1 Base Station Requirements for RavenXTG
PC running Campbell Scientific’s LoggerNet or PC400 software, with access
to the Internet.
4.2 Datalogger Site Equipment
RavenXTG modem with power cable (included with modem).
Datalogger—21X, CR510, CR10(X), CR23X, CR7, CR1000, CR5000,
CR3000, CR800.
Modem Interface
If connecting to CS I/O port:
SC105 or SC932A Interface—connects the modem to the 21X,
CR510, CR10(X), CR7, or other dataloggers’ CS I/O port.
The SC105 must be configured for use with the modem using the
Device Configuration Utility. Settings should be:
CS I/O Mode: SDC Address 7
RS-232 Mode: Modem
Baud Rate: 115.2K or 9600 baud depending on datalogger model
8 data bits, 1 stop bit, no parity
If connecting to RS-232 port:
PN 18663 Null Modem Cable—connects the modem to the
CR23X, CR3000, CR800, CR2XX, CR1000, or CR5000 RS-232
port.