Instruction manual
Appendix A. Wireless Ace Setup
without Template File
Wireless Ace 3G is used to program settings in the Raven XT-Rogers modem
to make the modem compatible with CSI dataloggers. Airlink template files to
send the modems are available on the Campbell Scientific website
(http://www.campbellsci.ca/download
). The procedure for sending the
template files is described in Section 5.
When the template files are not available, Wireless Ace 3G can be used to
change the settings described below.
For a direct connection on a COM port use PPP.
Make a note of the Device port (*DPORT). The default is 12345 and we use
6785 in our template. Any valid port can be used. This is the port number
used in LoggerNet to get to the datalogger.
A-1