Operator`s manual

44
Installation, Operation and Maintainance of Buoy Operated Automatic Meteorological Stations
Annexes
Annex 2: Wiring Diagram for CR10X Using BUOY_METSTAT Datalogger Program
G
HMP45C (1) clear
G
HMP45C (2) clear
G
05103 (1) black
H4
108W (1) red
05103 (1) clear
L4
108W (2) red
G
05103 (2) black
AG
Jumper to L5
05103 (2) clear
H5
Q -7.1 (FWSC) re d
108W (1) clear
L5
Q -7.1 (FWSC) black
Q -7.1 (FWSC) clear
Jumper to AG
H1
HMP45C (1) blue
AG
L1
HMP45C (1) yellow
H6
C100 orange
AG
HMP45C (1) purple
L6
Jumper to G
HMP45C (1) black
AG
HMP45C (2) purple
E3
HMP45C (2) black
AG
H2
HMP45C ( 2) blue
G
L2
HMP45C (2) yellow
G
Jumper to L6
AG
05103 (1) white
C100 black
05103 (2) white
108W (1) purple
108W (2) purple
H3
05103 (1) green
L3
05103 (2) green
AG
E1
05103 (1) blue
05103 (2) blue
108W (1) black
108W (2) black
AG
E2
G
C100 shield
108W (2) clear
P1
05103 (1) red
5V
G
5V
P2
05103 (2) red
G
G
SW 12V CTRL
C8
SW 12V
C7
G
C6
C5
C4
C3
C2
HMP45C (2) orange
C1
HMP45C (1) orange
G
12V
HMP45C (1) red
HMP45C (2) red
12V
C100 white
HMP45C (1): Vaisala Temperature and Relative Humidity Sensor at 2 m.
HMP45C (2): Vaisala Temperature and Relative Humidity Sensor at 4 m.
05103 (1): YOUNG Wind Speed and Direction Sensor at 2 m.
05103 (2): YOUNG Wind Speed and Direction Sensor at 4 m.
108W (1): Water temperature probe at 0 m.
108W (2): Water temperature probe at 20 m depth.
Q-7.1: Fritschen Net Radiometer
C100: KVH Digital compass