4.2.2 Installing/Changing the Battery
The BP24 power supply consists of a housing for and 24 AH battery. It is shown on figure 13, together with other
elements of the power supply.
Follow the below specified guidelines to replace the battery:
Disconnect power to the datalogger by toggling the switch to OFF;•
Clip off the battery connector from the terminal INT;•
Take out the battery;•
Put in the new battery, make sure the battery terminals are on the side of the regulator;•
Plug the battery connector into the INT terminal, make sure the clip is properly attached;•
Reconnect power to the datalogger by toggling the switch to ON;•
Figure 13: BP24 Power Supply for CR10X Storage and Control Module
INT Battery Terminal
Charging Indicator
ON/OFF Switch
Input Terminals Solar
Power Supply
12V Terminals to CR10X
Battery Connected to PS12LA Regulator