Operator`s manual
16
Installation, Operation and Maintainance of Buoy Operated Automatic Meteorological Stations
Sensor
HMP45C-2M (Temp & RH)
Sensor (1) at 2 Meters
HMP45C-4M (Temp & RH)
Sensor (2) at 4 Meters
Q-7.1 Net Radiometer
05103-Wind Speed & Dir
Sensor (1) at 2 Meters
05103-Wind Speed & Dir
Sensor (2) at 4 Meters
108 Water Temperature
Sensor (1) at 0 Meters
Depth
108 Water Temperature
Sensor (2) at 20 Meters
Depth
C100 Compass Engine
No
1
2
3
4
5
6
7
8
Color
Clear
Blue
Yellow
Purple
Black
Orange
Red
Clear
Blue
Yellow
Purple
Black
Orange
Red
Clear
Red
Black
Jumper from AG to L5
Jumper from L5 to AG
Black
Clear
White
Green
Blue
Red
Black
Clear
White
Green
Blue
Red
Clear
Purple
Black
Red
Clear
Purple
Black
Red
Shield
White
Orange
Black
Jumper from 6L to G
Jumper from G to 6L
Terminal
G
H1
L1
AG
AG
C1
12V
G
H2
L2
AG
AG
C2
12V
G
H5
L5
G
G
AG
H3
E1
P1
G
G
AG
L3
E1
P2
G
AG
E1
H4
G
AG
E1
L4
G
12V
H6
G
Table 1: Wiring Schedule
CR10X Storage and Control Module
After connecting all sensors to the wiring panel, the user should load an appropriate datalogger program into
the CR10X. To do this, store the BUOY_METSTAT1 datalogger program in Program Location 7 of the SM4M storage
module for the station at Kalabshah Khor; and BUOY_METSTAT2 in Program Location 8 of the SM4M for the station
at Toshka Khor (see Annex 6 for the complete instructions for this activity). After storing the datalogger programs in
SM4M, connect the SM4M storage module and CR10KD keyboard display to the logger using the SC12 cable.