Instruction manual

PC208 INTRODUCTION
3
TABLE I-1. File Types Used With PC208 Software
EXTENSION MNEMONIC of EXT. DESCRIPTION/USES
TYPE and SOFTWARE that
generated file
.DAT raw DATa Data as received from datalogger. Format
PC208E, TELCOM, SMCOM, GT can be Printable ASCII, comma separated, or
Final Storage Format.
.STN STatioN parameter Parameters necessary to call datalogger.
PC208E, TELCOM, GT
.ERR ERRor log file Record of communication errors. ASCII file.
PC208E, TELCOM
.CQR Communication Quality Report Record of communication quality from RF
PC208E, TELCOM Modem shut down blocks, ASCII file. See
Radiotelemetry Manual Section 3.1.7.3.
.CSI datalogger program file Documentation of datalogger program.
EDLOG
.DLD DownLoaD program to datalogger EDLOG generates this down-loadable file.
PC208E, EDLOG, GT GT also uses extension when saving program
from datalogger. Can also be fed into EDLOG
to develop .DOC file.
.INI INItialization file for modems Telcom and GT use this file to configure the
PC208E, TELCOM, GT telephone modem.
.LBR LiBRary file Contains group of program instructions.
EDLOG
.PDF Printable Document File Produced by EDLOG for subsequent printing
EDLOG or use in a standard text editor.
.RPT data RePorT file Produced by SPLIT for subsequent printing
SPLIT or use in a standard text editor.
.PRN PRiNtable data file Produced by SPLIT for subsequent use by Lotus
SPLIT or other spreadsheet programs.
.PAR PARameter file Contains parameters used by SPLIT for data
SPLIT selection and processing.
.OBJ OBJect file Code for PROM from GT create Power-Up
GT option.
.SCR SCRipt or Schedule List of station files for data collection.
PC208E, TELCOM
.FSL Final Storage Labels Information on the data that a datalogger
EDLOG program will produce.
.PTI Program Trace Information Timing information on a datalogger program.
EDLOG