Instruction manual
23
2: 60 Mod/By
3: 93 Loc [ _________ ]
31: Z=X+Y (P33)
1: 92 X Loc [ _________ ]
2: 93 Y Loc [ _________ ]
3: 92 Z Loc [ _________ ]
32: Beginning of Loop (P87) Reset all storage arrays
1: 0 Delay
2: 90 Loop Count
33: Z=F (P30)
1: 0 F
2: 0 Exponent of 10
3: 1 -- Z Loc [ _________ ]
34: End (P95)
35: Volts (SE) (P1) Measure initial temp signal and store in loc (41..52)
1: 12 Reps Change as required
2: 4 ñ 250 mV Slow Range
3: 1 SE Channel
4: 41 Loc [ _________ ] Monitor loc (41..52) to observe initial temp signal
5: 1 Mult
6: 0 Offset
36: Timer (P26) Reset timer
1: 0 Loc [ _________ ]
37: Do (P86)
1: 21 Set Flag 1 Low
38: Do (P86)
1: 12 Set Flag 2 High
39: End (P95)
40: If Flag/Port (P91) Flag 2 is used to initiate the heat-pulse
1: 12 Do if Flag 2 is High
2: 30 Then Do
41: Set Port(s) (P20)
1: 0 C8..C5 = 0/0/0/0
2: 111 C4..C1 = 0/high/high/high
42: Beginning of Loop (P87)
1: 1 Delay
2: 0 Loop Count
43: Timer (P26)
1: 99 Loc [ _________ ]
44: IF (X<=>F) (P89) Fire a 2 s heat pulse
1: 99 X Loc [ _________ ]