Sever communications is 6784. The correct port number must follow
the IP address of the NL200 in LoggerNet Setup in order for
LoggerNet to communicate through the NL200. For example, if the
NL200 is configured as a CS I/O Serial Server, in LoggerNet Setup
enter the correct IP address of your NL200 followed by :6783 (e.g.,
192.168.0.3:6783).
6. If you are unable to communicate with the NL200 via the USB cable,
verify that you have installed the latest drivers for the NL200. These can
be downloaded from our website, www.campbellsci.com
.
7. If the NL200 is configured as a CS I/O Serial Server, verify that any other
SDC device attached to the datalogger is using a different SDC address.
For example, if the NL200 is configured for SDC7, any other device
attached to the datalogger cannot use SDC7.
8. If communicating over a slow or intermittent connection, it may be
necessary to lower the Maximum Packet Size of the datalogger in
LoggerNet Setup and/or add Extra Response Time to the PakBus Port in
LoggerNet Setup.
9. Reset the NL200 to its default settings.
• If none of the above steps correct your communication problems, reset
the NL200 to its default settings. This can be done using the Factory
Defaults button in DevConfig or by using the Defaults command in a
telnet session with the NL200.