Product manual
NL200 Network Link Interface
• You can verify your settings are correct by selecting the datalogger in the
Network Map, selecting the Clock tab, and pressing “Check Clocks”. If
your settings are correct, you should see the current clock of your server
and datalogger.
FIGURE 7-1. Bridge Mode LoggerNet Setup
7.1.5 Connect
You are now ready to connect to your datalogger using the LoggerNet Connect
Screen.
7.2 Serial Server
The NL200 can tunnel RS-232 and CS I/O serial communications over
Ethernet. Any packet sent to the configured Ethernet IP port will have the IP
layer removed, and the serial data is then directed to the serial connection.
7.2.1 Physical Set-up
Power the NL200 through the barrel connector jack located on the edge of the
device. Connect the NL200 to your local network using an Ethernet cable,
attaching one end to the NL200's Ethernet port and the other end to your
network. Connect the supplied SC12 serial cable from the NL200’s CS I/O
port to the datalogger’s CS I/O port or from the NL200’s RS-232 port to the
datalogger’s RS-232 port.