Instruction manual

NL200/201 Network Link Interface
You can verify your settings are correct by selecting the datalogger in the
Network Map, selecting the Clock tab, and pressing Check Clocks. If
your settings are correct, you should see the current clock of your server
and datalogger.
FIGURE 7-3. Serial server LoggerNet setup
7.3.4 Connect
You are now ready to connect to your datalogger using the LoggerNet Connect
screen.
7.3.5 Serial Sensors
The NL200/201 configured as an RS-232 serial server as described above can
be used to communicate with a serial sensor. However, LoggerNet is not
capable of communicating with the serial sensor. You must have some other
method of communicating with the sensor.
7.4 TCP Serial Client
When the RS-232 port is configured as TCP Serial Client, the NL200/201 will
initiate and maintain a TCP socket connection to the IP address and port
number specified by the Serial Client Address and Serial Client Port
settings. Data received on the RS-232 port will be forwarded to this TCP
18