Instruction manual

NL200/201 Network Link Interface
However, an allowed neighbors list can be useful in restricting
communication paths.
On the Network Services tab:
o Make note of the PakBus\TCP Server Port. (The default
PakBus/TCP Server Port is 6785. Unless firewall issues exist, it is
not necessary to change the port from its default value.)
CS I/O PakBus® Router
Connect to the NL200/201 in DevConfig (see Section 6, Configuring the
NL200/201
(p. 9)).
On the NL200 tab:
o Set Bridge Mode to disable.
On the CS I/O tab:
o Set Configuration to PakBus.
o Set SDC address. (Note that if multiple peripherals are connected to
a datalogger’s CS I/O port, each must have a unique SDC address.)
o Set Beacon Interval and Verify Interval as described above. Often
the default values can be used.
On the Network Services tab:
o Make note of the PakBus\TCP Server Port. (The default
PakBus/TCP Server Port is 6785. Unless firewall issues exist, it is
not necessary to change the port from its default value.)
7.1.3 LoggerNet Setup
In the LoggerNet Setup screen, press Add Root and choose IPPort. Input
the NL200/201s IP address and port number. The IP address and port
number are input on the same line separated by a colon.
Add a PakBus® Port (PakBusPort).
Add a PakBus® Router (pbRouter). Input the PakBus address of the
NL200/201. The NL200/201’s default PakBus address is 678.
Add the datalogger and input the PakBus® address of the datalogger.
Press Apply to save the changes.
13