Product manual

Section 1. NL115 Ethernet/CompactFlash
®
Module Overview
Software Requirements: LoggerNet 3.2 or later
PC400 1.3 or later
Dimensions: 4.0" x 3.5" x 2.5" (10.2 x 8.9 x 6.4 cm)
Weight: 5.4 oz (154 g)
FIGURE 1-1. NL115 Ethernet/CompactFlash Module
1.2 Physical Description
The NL115 connects to a datalogger peripheral port and has a 10 Base T
Ethernet port.
It also has a slot for a Type I or Type II CompactFlash (CF) card (3.3V, 75
mA).
There is one red-green-orange LED (light emitting diode) and two buttons:
control and eject. The LED indicates the status of the module. The LED will
flash red when the CF card is being accessed, solid green when it is OK to
remove the card, solid orange to indicate an error, and flashing orange if the
card has been removed and has been out long enough that CPU memory has
wrapped and data is being overwritten without being stored to the card. The
control button must be pressed before removing a card to allow the datalogger
to store any buffered data to the card and then power it off. The eject button is
used to eject the CF card. Note that if the eject button cannot be pressed, it
may have been disabled by bending it to the right. Straighten and then press
the eject button to eject the CF card.
1-2