Instruction manual

NL115 Ethernet and CompactFlash
®
Module
EMI and ESD Protection: Meets requirements for a class A device
under European Standards
Application of Council Directive(s):
89/336/EEC as amended by 89/336/EEC
and 93/68/EEC
Standards to which conformity is declared:
EN55022-1; 1995 and EN50082-1: 1992
Cable Requirements: Use a straight-through Ethernet cable
when the cable is run from the hub to the
NL115. Use a crossover Ethernet cable
when the cable is run directly from the
computer to the NL115. Use a shielded
cable and/or the 28033 surge suppressor
when the cable length is more than 9 ft.
The maximum recommended segment length for 10BaseT
networks using CAT5 cable is 100 meters. Segment length is the
length of cable between the NL device and the Ethernet repeater,
hub, switch, or router it is connected to.
Ethernet Speed: 10Base-T (10 Mbps), half-duplex
Typical Access Speed: 200 to 400 kbits s
–1
Memory Configuration: User-selectable for either ring style
(default) or fill-and-stop.
Software Requirements: LoggerNet 3.2 or later
PC400 1.3 or later
Dimensions: 10.2 x 8.9 x 6.4 cm (4.0 x 3.5 x 2.5 in)
Weight: 154 g (5.4 oz)
FIGURE 6-1. NL115 Ethernet/CompactFlash Module
NOTE
8