4: 30       Then Do
14:  Z=F (P30)
1: 100      F
     2: 00      Exponent of 10
     3: 2       Z Loc [ RH        ]
15:  End (P95)
;IF RH>100, SET RH=100
16:  Saturation Vapor Pressure (P56)
  1: 1       Temperature Loc [ AIR_TEMP  ]
  2: 7       Loc [ SVP      ]
;CALCULATING SATURATED VAPOR PRESSURE AS FUNCTION OF AIR TEMPERATURE
;IN KILO PASCAL [KPA]
17:  Z=X*F (P37)
  1: 2       X Loc [ RH       ]
  2: 0.01     F
  3: 8       Z Loc [ VP       ]
;THIS EQUATION CALCULATED THE FIRST STEP IN “VP=RH/100*SVP”
18:  Z=X (P31)
  1: 8       X Loc [ VP       ]
  2: 9       Z Loc [ AUX_SVP   ]
;AUXILIARY STEP
19:  Z=X*Y (P36)
  1: 9       X Loc [ AUX_SVP   ]
  2: 7       Y Loc [ SVP      ]
  3: 8       Z Loc [ VP       ]
;THIS IS THE RESULTING STEP IN “VP=RH/100*SVP”, IN [KPA]
20:  Z=X-Y (P35)
  1: 7       X Loc [ SVP      ]
  2: 8       Y Loc [ VP       ]
  3: 10      Z Loc [ VPD      ]
;CALCULATING “VPD=SVP-VP”, VPD = VAPOR PRESSURE DEFICIT, IN [KPA]
21:  If (X<=>F) (P89)
  1: 3       X Loc [ SOLAR_RAD ]
  2: 4       <
  3: 0.0      F
  4: 30      Then Do
    22:  Z=F (P30)
     1: 0.0     F
     2: 00      Exponent of 10