Instruction manual
Appendix B. Example Program 
The following CR1000 program measures the 034B every 5 seconds, and store 
mean wind speed, unit vector mean direction, and standard deviation of the 
direction every 60 minutes. Wiring for the examples is given in TABLE B-1. 
TABLE B-1. Wiring for Example Program 
Color  Description  CR1000 
Red  Wind Spd. Signal   P1 
Black  Wind Spd. Reference  
Green  Wind Dir. Signal   SE 1 
Blue  Wind Dir. Excitation   EX 1 
White  Wind Dir. Reference  
Clear  Wind Dir. Shield  
'CR1000 
'Declare Variables and Units 
Public Batt_Volt 
Public WS_ms 
Public WindDir 
Units Batt_Volt=Volts 
Units WS_ms=meters/second 
Units WindDir=degrees 
'Define Data Tables 
DataTable(Table1,True,-1) 
  DataInterval(0,60,Min,10) 
  WindVector (1,WS_ms,WindDir,FP2,False,0,0,0) 
  FieldNames("WS_ms_Avg,WindDir_Avg,WindDir_StDev") 
EndTable 
'Main Program 
BeginProg 
  Scan(5,Sec,1,0) 
    'Default Datalogger Battery Voltage measurement Batt_Volt: 
    Battery(Batt_Volt) 
    '034A/034B Wind Speed & Direction Sensor measurements WS_ms and WindDir: 
    PulseCount(WS_ms,1,1,2,1,0.7989,0.28) 
    If WS_ms=0.2811 Then WS_ms=0 
    BrHalf(WindDir,1,mV2500,1,1,1,2500,True,0,_60Hz,720.0,0)  'Use 5000 mV  
    If WindDir>=360 OR WindDir < 0 Then WindDir=0  'excitation for  
    'Call Data Tables and Store Data  'the CR3000 and  
    CallTable(Table1)    'CR5000 dataloggers 
  NextScan 
EndProg 