7.2  Mounting Options 
The 034B can be attached to a CM200-series crossarm via a 17953 NU-RAIL 
fitting or a CM220, Right Angle Mounting Bracket.  Procedure for using these 
mounts is provided in the Quickstart (Section 4.1, Step 1—Mount the Sensor).  
Alternatively, the 034B can be attached to the top of a CM106B, CM110, 
CM115, or CM120 tripod via the CM216, Sensor Mounting Kit.  The CM216 
extends 10 cm (4 in) above the mast of the tripod. 
FIGURE 7-1. CM216 mount 
7.3  Wiring 
Connections to Campbell Scientific CRBasic dataloggers are given in TABLE 
7-1. To wire an Edlog datalogger, see an older manual at 
www.campbellsci.com/old-manuals, or contact a Campbell Scientific 
application engineer for assistance. 
TABLE 7-1. Connections to Campbell Scientific Dataloggers 
Color 
Wire Label 
CR6 
CR9000X 
CR800 
CR5000 
CR3000 
CR1000 
CR200(X) 
Red 
WS Signal 
Pulse 
P_SW 
Black 
WS Signal Ref 
Green 
WD Signal 
SE Analog 
SE Analog 
Blue 
WD Volt Excite 
Excitation (VX or EX) 
Excitation (VX or EX) 
White 
WD Signal Ref 
Clear 
Shield 
9 