Instruction manual
Met One 034B Wind Set 
8.  If LoggerNet, PC400, RTDAQ, or PC200W is running on your PC, 
and the PC to datalogger connection is active, you can click Finish in 
Short Cut and you will be prompted to send the program just created 
to the datalogger. 
9.  If the sensor is connected to the datalogger, as shown in the wiring 
diagram in step 6, check the output of the sensor in the datalogger 
support software data display to make sure it is making reasonable 
measurements. 
5.  Overview 
The 034B, Wind Set is used to measure horizontal wind speed and direction.  
Wind speed is measured with a three cup anemometer. Rotation of the cup 
wheel opens and closes a reed switch at a rate proportional to wind speed.  
Vane position is transmitted by a 10 kΩ potentiometer. With a precision 
excitation voltage applied, the output voltage is proportional to wind direction. 
The accompanying Met One manual contains additional information on the 
operating principals, installation, and maintenance of the sensor. The Met One 
manual is also available at their website (www.metone.com). 
Cable length for the 034B is specified when the sensor is ordered. TABLE 5-1 
gives the recommended cable length for mounting the sensor at the top of the 
tripod/tower with a CM202 crossarm. 
TABLE 5-1. Recommended Cable Lengths 
CM106  CM110  CM115  CM120  UT10  UT20  UT30 
11 ft  14 ft  19 ft  24 ft  14 ft  24 ft  37 ft 
The 034B’s cable can terminate in: 
•  Pigtails that connect directly to a Campbell Scientific datalogger 
(option –PT). 
•  Connector that attaches to a prewired enclosure (option –PW).  Refer 
to www.campbellsci.com/prewired-enclosures for more information. 
•  Connector that attaches to a CWS900, Wireless Sensor Interface 
(option –CWS).  The CWS900 allows the 034B to be used in a 
wireless sensor network.  Refer to www.campbellsci.com/cws900 for 
more information.  
6.  Specifications 
Features: 
•  Designed for continuous, long term, unattended operation in adverse 
conditions  
•  Constructed of light-weight aluminum  
•  Compatible with Campbell Scientific CRBasic dataloggers: CR6, 
CR200(X) series, CR800 series, CR1000, CR3000, CR5000, and 
CR9000X 
7 