Instruction manual
Met One 034B Wind Set 
determining True North using a compass and the magnetic declination for 
the site.  
7.  Remove the alignment screw at the base of the 034B (FIGURE 4-1). 
8.  Insert the 034B into the aluminum bushing provided with the sensor (see 
FIGURE 4-1). 
9.  Align the hole in the bushing with that in the 034B base and replace the 
screw (see FIGURE 4-1). 
10. Insert the 034B/bushing into the NU-RAIL fitting (FIGURE 4-1) or the 
CM220’s U-bolt (FIGURE 4-2). 
11. Align the sensor so that the counter weight points to true South and tighten 
the set screws on the NU-RAIL or U-bolts on the CM220. Final sensor 
orientation is done after the datalogger has been programmed to measure 
wind direction as described in Appendix C. 
12. Remove the shoulder screw to allow the vane to rotate (see FIGURE 4-1). 
13. Attach the sensor cable to the six pin male connector on the 034B.  Make 
sure the connector is properly keyed.  Finger tighten the knurled ring. 
14. Route the sensor cable along the underside of the crossarm to the tripod or 
tower, and to the instrument enclosure. 
15. Secure the cable to the crossarm and tripod or tower using cable ties. 
FIGURE 4-1. 034B mounted on a crossarm using a 17953 NU-RAIL 
crossover fitting 
3 