Instruction manual

SECTION 3. REPORT: SPLIT
3-22 PC208W, Version 3.0, Instruction Manual
This .PAR file produces a wind chill summary of
the Mt. Logan Peak data set. The formula for
calculating wind chill is given as follows:
Te = 33-(h/22.066)
where
Te = Wind Chill equivalent
temperature, degrees C
h = ((100V).5 + 10.45-V)(33-t)
where
h = Kcal m
-2
hr
-1
wind chill index
v = wind speed in meters/second
t = temperature in degrees C
Note that at low wind speeds this formula gives
wind chill temperatures that are greater than the
ambient temperature. The formula is for
example purposes and is not endorsed by
Campbell Scientific as a standard.
When this .PAR file is executed, the following
output is displayed on the screen.