x Be sure to have the domain, account username, and password details
available so that they can be entered into the modem configuration, as
well as the LoggerNet setup.
x Enter details into the modem configuration
5.3.6 Serial Port Configuration (COM1/COM2)
In order for the modem to communicate with a Campbell Scientific datalogger,
the modem’s serial port must be properly configured. The IPn3Gb has two 9-
pin serial ports. The COM1 (Data) port can be used for either a TCP server or
PPP configuration. The COM2 (Diagnostic) port can only be used for TCP
server configuration. When required, both ports can be used simultaneously to
provide access to two dataloggers or other serial devices.
A PPP configuration is recommended for CR800 series, CR1000, or CR3000
dataloggers, as it allows access to the connected datalogger’s IP functionality