Instruction manual
HS2 and HS2P 
The HydroSense II is an easy-to-use, portable device for measuring volumetric 
water content of soil. The major components of the system are the display, the 
sensor, and the software.  A sensor with 12 cm rods (model CS659 or CS659P) 
and a sensor with 20 cm rods (model CS658 or CS658P) are available. 
Campbell Scientific offers the HS2, the standard HydroSense II system, and 
the HS2P, a HydroSense II system with a strong handle and pole. FIGURE 
1-1, HS2 HydroSense II System (p. 1) shows the HS2 and FIGURE 1-2, HS2P 
HydroSense II Pole System (p. 1) shows the HS2P. 
Throughout the manual, HydroSense II refers to both the HS2 and 
HS2P, unless specified otherwise. 
2.  Cautionary Statements 
•  The connectors that connect the HydroSense II display to the sensor are a 
push-pull type with locators to align the connectors. DO NOT TWIST. 
The connectors can be damaged if the user twists them or attempts to 
screw or unscrew them. 
•  Remove the AA batteries before putting the HydroSense II display into 
storage. 
•  An unobstructed view of the sky may be required to achieve the most 
accurate global position data possible from the HydroSense II GPS. 
•  Sensor rods must be completely inserted into the soil before making a 
measurement. 
3.  Quickstart 
1.  Remove the HS2 display or HS2P from the carry case. 
2.  Remove the blue protective strip from the display window. 
Steps 3 and 4 are for the HS2 only because the HS2P comes fully 
assembled.  If using an HS2P, go directly to step 5. 
3.  Remove the HS2 sensor from the carry case. 
4.  Connect the HS2 sensor to the display by mating the connector on the 
cable to the connector at the bottom of the display. DO NOT TWIST the 
connectors. 
The connector is a push-pull type with locators to align the 
connectors.   The connectors can be damaged if the user 
attempts to screw or unscrew them.   To mate the 
connectors, simply bring them together and turn until they 
are aligned, then applying firm pressure, slide them together 
until they click.  To disconnect, pull back on the connector 
collar with the thumb  and forefinger and pull the two 
connectors apart. 
NOTE 
NOTE 
CAUTION 
2 