Product manual

Model HC2S3 Temperature and Relative Humidity Probe
4: Volt (SE) (P1)
1: 1 Reps
2: 25 2500 mV 60 Hz Rejection Range
3: 4 SE Channel
4: 1 Loc [ RH ]
5: 0.1 Multiplier
6: 0 Offset
5: Do (P86) ;Turn off switched 12V
1: 51 Set Port 1 Low
6: If (X<=>F) (P89)
1: 1 X Loc [ RH ]
2: 3 >=
3: 100 F
4: 30 Then Do
7: If (X<=>F) (P89)
1: 1 X Loc [ RH ]
2: 4 <
3: 103 F
4: 30 Then Do
8: Z=F x 10^n (P30)
1: 100 F
2: 0 n, Exponent of 10
3: 1 Z Loc [ RH ]
9: End (P95)
10: End (P95)
11: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 10 Set Output Flag High (Flag 0)
12: Set Active Storage Area (P80)
1: 1 Final Storage Area 1
2: 101 Array ID
13: Real Time (P77)
1: 1220 Year,Day,Hour/Minute (midnight = 2400)
14: Average (P71)
1: 1 Reps
2: 2 Loc [ AirTC ]
15: Sample (P70)
1: 1 Reps
2: 1 Loc [ RH ]
16