Model HC2S3 Temperature and Relative Humidity Probe
The HC2S3-L's cable can terminate in:
• Pigtails that connect directly to a Campbell Scientific datalogger
(cable termination option –PT; see Section 4).
• Connector that attaches to a prewired enclosure (cable termination
option –PW).
• Connector that attaches to a CWS900 Wireless Sensor Interface (cable
termination option –CWS). The CWS900 enables the probe to be used
in a wireless sensor network.
• Connector that attaches to the Temp/RH connector on a CS110
Electric Field Meter or ET-series weather station (cable termination
option –C).
• Military-style connector that attaches to the Temp/RH connector on a
RAWS-P Permanent Remote Automated Weather Station (cable
termination option –RQ).
The HC2S3-QD is included with the RAWS-F Quick Deployment Remote
Automated Weather Station and can be ordered as a replacement part. Its cable
has a 65-in. length and terminates in a military-style connector that attaches to
the Temp/RH connector on the RAWS-F connector panel.
6. Specifications
Features:
• Well-suited for long-term, unattended applications
• Accurate and rugged
• Compatible with all Campbell Scientific dataloggers (including the
CR200(X) series)
Compatibility: CR200(X) series
CR800 series
CR1000
CR3000
CR5000
CR9000(X)
CR7X
CR510
CR10(X)
CR23X
21X
Operating Limits at Electronics: -40° to +100°C
Storage Temperature: -50° to +100°C
Probe Length: 85 mm (3.3 in.), 183 mm (7.25 in.)
including connector
Probe Diameter: 15 mm (0.6 in.)
Probe Weight: 10 g (0.35 oz)
Filter: Polyethylene or Teflon (optional,
ordered separately)
8