Specifications

Section 1. Installation and Maintenance
1-9
TABLE 1.3-3. PS100, Battery, and AC Transformer Specifications
Input Voltage (CHG terminals)
15 to 28 VDC or 18 VAC RMS
Battery Connections
Charging Output Voltage: Temperature compensated float
charge for 12 V Battery
Temperature Compensation Range: -40 to +60ºC
Charging Current Limit: 1.2 Amps typical
Power Out (+12 terminals)
Voltage: Unregulated 12 V from Battery
Current Limited w / 3 A Thermal Fuse:
> 3 A @ < 20°C
3 A @ 20°C
2.1A @ 50°C
1.8 A @ 60°C
Batteries
Operating Temperature Range: -40 to +60ºC
Capacity:
PS100 7 Amp hours
BP12 12 Amp hours
BP24 24 Amp hours
AC Transformer: CSI Model No. 9591
Input Voltage: 120 VAC
Output Voltage: 18 VAC RMS
Output Current (max): 1.2 Amps RMS
Protection (automatic reset):
85°C thermal reset breaker
UL Approval: UL-1950
AC Transformer: CSI Model No. 14014
Input Voltage: 90 - 264 VAC; 47 - 63 Hz
Output Voltage: 18 VDC
Output Current (max): 1.3 Amps
UL Approved, File No.: E137895
There are inherent hazards associated with the use of sealed lead acid batteries.
See section 1.3.2 for details.
1.3.3.3 CH100
The CH100 contains the same circuitry as the PS100. It is used to float charge
an external 12 VDC Yuasa battery using AC or solar power. No internal
batteries are contained in the CH100. Other power supply options are
connecting a 12-volt battery directly to the CR3000, Section 1.5, or supplying
power from a vehicle, Section 1.6.