Specifications
A-1
Appendix A. CR3000 Status Table
The CR3000 status table contains current system operating status information
that can be accessed from the running CR3000 program or monitored by PC
software. There is also a way to view the status information from the
keyboard. Table 1 shows the variables in the status table and a brief
explanation of each follows.
Status Fieldname Description Variable
Type
Default Normal
Range
User can
change?
Info
Type
FileMark A value created by the PC software _
RecNum The record number for this set of data _ _ _
TimeStamp The time the record was generated Time _ _ _
OSVersion The version of the Operating System String _ _ _ Status
OSDate Date the OS was released. String _ _ _ Status
OSSignature The Operating System Signature Integer _ _ _ Status
SerialNumber Machine specific serial number. Stored
in FLASH memory.
Integer _ _ _ Status
RevBoard Hardware revision number. Stored in
FLASH memory.
Integer _ _ _ Status
StationName
1
Name of the machine. Stored in
FLASH memory.
String _ Yes Config
PakBusAddress
2
Logger PakBus address. Integer 1 1 to 3999 Yes Config
PB
ProgName Running program name. String _ _ _ Status
StartTime Time that the program began running. Time _ _ _ Status
RunSignature Signature of the current running
program file.
Integer _ _ _ Status
ProgSignature Signature of the compiled binary data
structure for the current program. This
value is independent of comments
added or non functional changes to the
program
Integer _ _ _ Status
Battery Current value of the battery voltage.
This measurement is made in the
background calibration.
Float _ 9.6-16
Volts
_ Measu
re
PanelTemp Current panel temperature
measurement. This measurement is
made in the background calibration.
Float _ _ _ Measu
re
WatchdogErrors
3
The number of Watchdog errors that
have occurred while running this
program.
Integer 0 0 Can Reset
= 0
Error
LithiumBattery
4
Current value of the Lithium battery
voltage. This measurement is updated
in the background calibration.
Float _ 2.7-3.6
Volts
_ Measu
re