Specifications
Section 6. CR1000 Power Supply
6-2
(ground). The CR1000 is internally protected against, but will not function
with, reversed external power polarity.
6.5 Vehicle Power Connections
If a CR1000 is powered by a motor vehicle supply, a second supply may be
needed. When starting the motor of the vehicle, the battery voltage may drop
below 9.6 V. This causes the CR1000 to stop measurements until the voltage
again equals or exceeds 9.6 V. A second supply can be provided to prevent
measurement lapses during vehicle starting. FIGURE 6.5-1 illustrate how a
secon
d power supply should be connected to the CR1000. The diode OR
connection causes the supply with the largest voltage to power the CR1000 and
prevents the second backup supply from attempting to power the vehicle.
CR1000
Panel
+12V
G
FIGURE 6.5-1. Connecting CR1000 to Vehicle Power Supply