Specifications
Section 2. Quickstart Tutorial
2-14
Step 3: Data Storage Output Processing.
The Outputs page has a list of Selected Sensors to the left, and data storage
Tables to the right as shown in FIGURE 2.2-6. Two Tables, Table1 and
Tabl
e2, are available by default. Both Tables have a Store Every field and a
list box to select time units. These are used to set the interval at which data
will be stored.
FIGURE 2.2-6. Short Cut Outputs Page
This exercise calls for one-minute data storage processing, so only one data
table is needed. To remove Table2, click on Table2 tab to activate it, and click
the Delete Table button.
The Table Name field is the name that will be used for the Table in which data
is stored. Change the default name of Table1 to OneMin, and change the
interval to 1 minute.
To add a measurement to data storage Table OneMin, highlight a measurement
under Selected Sensors (Batt_Volt) and click the appropriate processing button
(Average). Select the Batt_Volt, PTemp_C, and Temp_C measurements and
apply Average processing to each to add them to the OneMin Table
measurements.
Click Finish and name the file “Quickstart” to continue with Step 4 and
complete the program.
Step 4: Program Finish.
As shown in FIGURE 2.2-7, any errors the compiler may have detected are
d
isplayed, along with the names of the files that were created. The file
Quickstart.CR1 is the program file that is to be sent to the CR1000.
Quickstart.def is a summary of the sensor wiring and measurement labels.