Specifications
Appendix B. Status Table
B-2
TABLE B-2. Status Fields and Descriptions
Status Fieldname Description Variable
Type
Default Normal
Range
User can
change?
Info
Type
RecNum Record number for this set of data _ _ _
TimeStamp Time the record was generated Time _ _ _
OSVersion Version of the Operating System String _ _ _ Status
OSDate Date OS was released. String _ _ _ Status
OSSignature Operating System Signature Integer _ _ _ Status
SerialNumber CR1000 specific serial number. Stored
in FLASH memory.
Integer _ _ _ Status
RevBoard Hardware revision number. Stored in
FLASH memory.
Integer _ _ _ Status
StationName
1
Name of the CR1000. Stored in
FLASH memory.
String _ Yes Config
PakBusAddress
2
Logger PakBus address. String 1 1 to 3999 Yes Config
PB
ProgName Name of current (running) program. String _ _ _ Status
StartTime Time the program began running. Time _ _ _ Status
RunSignature Signature of the compiled binary data
structure for the current program. Value
is independent of comments added or
non-functional changes to the program
Integer _ _ _ Status
ProgSignature Signature of the current running
program file including comments.
Integer _ _ _ Status
Battery Current value of the battery voltage.
Measurement is made in the
background calibration.
Float _ 9.6-16
Volts
_ Measu
re
PanelTemp Current wiring panel temperature.
Measurement is made in the
background calibration.
Float _ _ _ Measu
re
WatchdogErrors
3
Number of Watchdog errors that have
occurred while running this program.
Integer 0 0 Can Reset
= 0
Error
LithiumBattery
4
Current voltage of the lithium battery.
Measurement is updated in background
calibration.
Float _ 2.7-3.6
Volts
_ Measu
re
Low12VCount
5
Number of occurrences of the 12VLow
signal being asserted. When this
condition is detected, the CR1000
ceases measurements and goes into a
low power mode until proper system
voltage is restored.
Integer 0 0 Can Reset
= 0
Error
Low5VCount Number of occurrences of the
5VExtLow signal being asserted.
Integer 0 0 Can Reset
= 0
Error
CompileResults Contains error messages generated by
compilation or during run time.
String _ 0 _ Error