Specifications
Section 2. Quickstart Tutorial
2-10
2.2.2 PC200W Software
Obtain and install PC200W. PC200W is available on the Campbell Scientific
Resource CD or at www.campbellsci.com.
When PC200W is first opened, the EZSetup Wizard is launched. Click the
Next button and follow the prompts to select the CR1000, the COM port on
the computer that will be used for communications, 115200 baud, and PakBus
Address 1. When prompted with the option to Test Communications, click
the Finish button.
If a datalogger was not added with the Wizard, click the + (add) button to
invoke the Wizard.
After exiting the EZSetup wizard, the Clock / Program tab is presented, as
shown in FIGURE 2.2-2. Current Datalogger Profile, Clock, and Datalogger
Program
features are integrated into this tab. Tabs to the right are used to
select Monitor Data and Collect Data options. Buttons to the right of the tabs
are used to run Split, View, and Short Cut applications.
FIGURE 2.2-2. PC200W Setup/Connect Tab
2.2.2.1 Programming with Short Cut
To assist with this exercise, a type T thermocouple is shipped with the CR1000
(packaged with the screwdriver). The thermocouple is a pair of 5-inch wires
with blue / red insulation, soldered together at one end.