Specifications

Section 8. CR1000 Configuration
8-9
ranges already set up. These controls will be disabled if the Verify Interval
value is set to zero.
Add Range will cause the range specified in the Begin and End range to be
added to the list of neighbors to the datalogger on the port specified by
Selected Port. This control will be disabled if the value of the Verify Interval
is zero or if the end range value is less than the begin range value.
Remove Range will remove the range specified by the values of the Begin and
End controls from the list of neighbors to the datalogger on the port specified
by Selected Port. This control will be disabled if the range specified is not
present in the list or if the value of Verify Interval is set to zero.
Help is displayed at the bottom of the Deployment tab. When finished, Apply
the settings to the datalogger. The Summary window will appear. Save or
Print the settings to archive or to use as a template for another datalogger.
Cancel causes the datalogger to ignore the changes. Read File provides the
opportunity to load settings saved previously from this or another similar
datalogger. Changes loaded from a file will not be written to the datalogger
until Apply is clicked.
8.3.1.3 Advanced Sub-Tab
FIGURE 8.3-5. DevConfig Deployment | Advanced Tab
Is Router allows the datalogger to act as a PakBus router.
PakBus Nodes Allocation indicates the maximum number of PakBus devices
the CR1000 will communicate with if it is set up as a router. This setting is
used to allocate memory in the CR1000 to be used for its routing table.