Instruction manual
Appendix B. Alternate Base Station Configurations
B-6
The RF Modem (RF1) works with the default settings. Each datalogger field
site needs the “Dialed Using RF95 Path:” set. This is the same address set in
the RF310M RF Modem.
This window shows a phone to RF base with measurement using a repeater to
get to CR10X5. Note the second RF modem connected to the CR10X4.
CR10X4 is used as a repeater. The “Dialed using RF95 Path:” includes the
CR10X4 address (15F) and the CR10X5 address (20F).