Instruction manual
CS650 and CS655 Water Content Reflectometers
8.1.2.1 Settings Editor Tab
The Settings Editor tab shows settings stored in the CS650 firmware. Settings
that may be modified include User Name, SDI-12 Address, and RS-232 Baud
Rate. Attempts to change any of the other settings will result in a “Commit
failed. Unrecognized error condition” error message. DevConfig polls the
CS650 every two seconds while connected and the results are displayed in the
Real-Time Measurements field (TABLE 8-2). This is useful for verifying
probe performance.
Default communication settings are 9600 baud, no parity, 1 stop bit, 8 data bits,
and no error checking. After any changes to CS650 settings, select Apply to
write the changes to the CS650 firmware. A configuration summary is then
shown. The summary may be printed or saved electronically for future
reference.
15