User manual
User Manual 
19 
 Minimum(1,Distance,FP2,0,0)  
 Average(1,Distance,FP2,False) 
 StdDev(1,Distance,FP2,False) 
 Maximum(1,Stage,FP2,0,0)  
 Minimum(1,Stage,FP2,0,0)  
 Average(1,Stage,FP2,False) 
 StdDev(1,Stage,FPs,False) 
 Sample (1,Error_Code,UINT2) 
EndTable 
'Read sensor every 60 seconds 
BeginProg 
 Scan(60,sec,1,0)  
  'Code for SDI-12 measurements: 
 SDI12Recorder(CS475,1,0,”M!”,1,0)  
  'Call the data table: 
 CallTable(Hourly)  
NextScan 
EndProg 
7.5.2 Edlog 
Dataloggers that are programmed with Edlog include the CR500, CR510, CR10(X), 
and CR23X. These dataloggers use Instruction 105 to read the sensor. 
Instruction 105 allows data to be collected from the radar sensor; each sensor 
requires a separate Instruction 105. 
Instruction 105 has the following parameters: 
Parameter 1 — Address. Valid addresses are 0 through 9; 65 through 90 (decimal 
value for ASCII upper-case letters); and 97 through 122 (decimal values for ASCII 
lower-case letters). 
Parameter 2 — Command. Refer to the Edlog help for the command codes used 
with this instruction. 
Parameter 3 — Port. Enter the datalogger port in which the datalogger is connected. 
Parameter 4 — Location. Enter the input location in which to store the results. 
Parameter 5 — Multiplier 
Parameter 6 — Offset 
Edlog allocates only one of the input locations needed for this 
instruction. Three input locations are required for this sensor. The 
additional input locations must be inserted manually using the Input 
Location Editor. For information on manually inserting input 
locations, refer to Manually Inserting Input Locations in the Edlog 
help. 
NOTE