User manual
CS475, CS476, and CS477 Radar Water Level Sensor 
12 
6.1 Radar Unit 
Frequency: ~26 GHz 
Electromagnetic Compatibility:  Emission to EN 61326; 
  Electrical Equipment Class B 
Pulse Energy: 1 mW maximum 
Beam Angle 
  CS475:  10° (3-in dia horn) 
  CS476, CS477:  8° (4-in dia horn) 
Power Requirements 
  Input Voltage:  9.6 to 16 Vdc 
  Surge Protection: 1.5 KVA 
Typical Current Drain with 12 V Power Supply 
  Sleeps: 4.7 mA 
  Measurement: 14 mA 
6.2 Environmental 
Operating Temperature Range:  –40° to +80°C 
Storage Ranges 
 Temperature:  –40° to +80°C 
 Relative Humidity:  20% to 80% RH 
Temperature Sensitivity:  average TK: 2 mm/10 K, 
    max 5 mm over the entire 
  temperature range of 
  –40°to +80°C 
Vibration Resistance:  Mechanical vibrations with 4 g 
    and 5 to 100 Hz 